WARRANTY
Your Little Giant product is guaranteed to be in perfect
condition when it leaves our Factory. It is warranted
against de
-
fective materials and workmanship for a period of 12
months (90 day warranty on Models 1-AA-OM, GKPK-SC,
PP-1,
PPS-1, PP-12, PPS-12, PP-230 and Cooler King) from
date of purchase by the user. No warranty on brush
wear on
Model 35-OM and impeller or cam in Models
PP-1, PP-12, PPS-12 and PP-230. Any product that should
fail for either of
the above two reasons and is still within the warranty
period, will be repaired or replaced if returned prepaid
to our Fac
-
tory. All defective products returned under warranty
will be fully inspected to determine “CAUSE OF FAILURE”
before
any warranty is approved. Little Giant will honor the
warranty within the warranty time period specified on
satisfactory
written proof of purchase.
DISCLAIMER: Any oral statements about the product
made by the seller, the manufacturer, the representatives
or any
other parties, do not constitute warranties, shall not
be relied upon by the user, and are not part of the contract
for sale.
Seller’s and manufacturer’s only obligation,
and buyer’s only remedy, shall be the replacement
and/or repair by the
manufacturer of the product as described above.
Neither seller nor the manufacturer shall be liable for
any injury, loss or
damage, direct, incidental or consequential (including,
but not limited to, incidental or consequential
damages for lost
profits, lost sales, injury to person or property, or any
other incidental or consequential loss), arising out of
the use or the
inability to use the product, and the user agrees
that no other remedy shall be available to it. Before
using, the user shall
determine the suitability of the product for his intended
use, and user assumes all risk and liability whatsoever
in connec
-
tion therewith. THE WARRANTY AND REMEDY
DESCRIBED IN THIS LIMITED WARRANTY IS
AN EXCLUSIVE
WARRANTY AND REMEDY AND IS IN LIEU OF ANY
OTHER WARRANTY OR REMEDY, EXPRESSED
OR IMPLIED,
WHICH OTHER WARRANTIES AND REMEDIES
ARE HEREBY EXPRESSLY EXCLUDED, INCLUDING,
BUT NOT
LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE.
Some States do not allow the exclusion or limitation
of incidental or consequential damages, so the above
limitation or
exclusion may not apply to you. This warranty gives
you specific legal rights, and you may also have other
rights which
vary from state to state.
Warranty will be VOID if any of the following conditions
are found:
1. Sealed motor housing opened.
2. Product connected to voltage other than indicated
on name plate.
3. Cord cut off to a length less than three feet.
4. Pump allowed to operate dry (fluid supply
cut off).
5. Pump used to circulate anything other
than fresh water, light oils, or other mild liquids
at approximately
room temperature.
6. Product abuse by customer.
The National Electric Code requires a Ground
Fault circuit interrupter (GFCI) be installed in the
branch circuit
supplying fountain equipment rated above
15 volts. Part number 599335, GFCI-1, is in stock and
we recommend
each pump be used with a GFCI.
KEEP THIS FOLDER
File this for safe keeping. It may be valuable to
you for service under the term of the warranty.
Model # ____________________________________________
Date of Purchase __________________________
Catalog # __________________________________________
Serial # ___________________________________
Name of Dealer _______________________________________________________________________________
LITTLE GIANT PUMP COMPANY
3810 N. Tulsa St. P. O. Box 12010 Oklahoma City,
OK 73112
Phone (405) 947-2511 Fax (405) 947-8720
©Copyright 2003Little Giant Pump Company
Form 993310–6/03
:
• INSTALLATION
• MAINTENANCE
• OPERATION
• REPAIR PARTS
INTRODUCTION
This instruction sheet will provide you with information required
to safely own and operate the Little Gi
-
ant MD series pumps. The pump you have purchased
is a magnetic driven pump. These “MD” series
pumps handle most mildly corrosive fluids such as low
concentrations of acids and alkalis in pH range of
5 to 9 at fluid temperatures up to 150ºF. The pump head
parts are made of glass filled polypropylene. The
spindle shaft and thrust washers are titanium. The impeller
driven magnet is uncoated ceramagnet A
(barium ferrite) type ceramic. O-ring seals are nitrile. The motor
is thermally protected.
This instruction sheet covers the standard models in this
pump series. This form is applicable to other
models in this series not listed by catalog number in the
replacement parts list section of this pamphlet. If
the catalog number of your pump is not listed in the replacement
parts section, then caution should be ex
-
ercised when ordering replacement parts. Always give the
catalog number of your pump when ordering
replacement parts.
The Little Giant unit you have purchased is of the
highest quality workmanship and material. It has
been engineered to give you long and trouble-free service.
The Little Giant pumps are carefully inspected, tested, and
packaged to insure safe operation and de-
livery. When you receive your pump, examine it carefully
to determine that there are no broken or dam-
aged parts that may have occurred during shipment. If
damage has occurred, make notation and notify
the firm from which you purchased the pump. They will
assist you in the replacement or repair, if required.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING
TO INSTALL, OPERATE OR SERV-
ICE THE LITTLE GIANT PUMP, KNOW THE PUMP APPLICATIONS,
LIMITATIONS, AND POTENTIAL
HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING
ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD
RESULT IN PERSONAL INJURY AND/OR
PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR
FUTURE REFERENCE.
SAFETY GUIDELINES
DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE
FLUIDS SUCH AS GASOLINE, FUEL OIL,
KEROSENE, ETC. DO NOT USE IN EXPLOSIVE ATMOSPHERES.
PUMP SHOULD ONLY BE USED
WITH LIQUIDS COMPATIBLE WITH PUMP COMPONENT
MATERIALS.
DO NOT HANDLE PUMP WITH WET HANDS OR WHEN
STANDING ON A WET OR DAMP SUR
-
FACE, OR IN WATER.
THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR
AND/OR GROUNDING TYPE AT
-
TACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC
SHOCK, BE CERTAIN THAT IT IS CON
-
NECTED TO A PROPERLY GROUNDED GROUNDING
TYPE RECEPTACLE.
THE NATIONAL ELECTRIC CODE REQUIRES
A GROUND FAULT CIRCUIT INTERRUPTER
(GFCI) BE INSTALLED IN THE BRANCH CIRCUIT
SUPPLYING FOUNTAIN EQUIPMENT, POOLS,
ETC.
IN ANY INSTALLATION WHERE PROPERTY DAMAGE
AND/OR PERSONAL INJURY MIGHT RE
-
SULT FROM AN INOPERATIVE OR LEAKING PUMP DUE
TO POWER OUTAGES, DISCHARGE LINE
BLOCKAGE, OR ANY OTHER REASON, A BACKUP
SYSTEM(S) AND/OR ALARM SHOULD BE
USED.
SUPPORT PUMP AND PIPING WHEN ASSEMBLING AND
WHEN INSTALLED. FAILURE TO DO
SO MAY CAUSE PIPING TO BREAK, PUMP TO
FAIL, MOTOR BEARING FAILURES, ETC.
INSTRUCTIONS
AND
REPAIR
PARTS
FOR
3X-MDX
3-MDX
Page view 0
1 2

Summary of Contents

Page 1 - LITTLE GIANT PUMP COMPANY

LIMITEDLIMITEDWARRANTYLITTLE GIANT WARRANTY STATEMENTWARRANTYYour Little Giant product is guaranteed to be in perfectcondition when it leaves our Fact

Page 2 - SERVICE INSTRUCTIONS

ELECTRICAL CONNECTIONSCheck the pump label for proper voltage required. Donot connect to voltage other than that shown.If pump is supplied with a 3-pr

Comments to this Manuals

No comments